The JetMaster from sister company mycon GmbH is environmentally friendly and saves resources. The water consumption is extremely low at 0.20 – 1.00 l clear water per minute of use. JetMaster works without the addition of chemicals. In contrast to other aqueous cleaning processes, this also greatly reduces the amount of wastewater, which is only contaminated by the mostly harmless soiling of the surfaces in this area. An investigation of the LuKo in a customer’s system revealed some surprising findings. The performance of the tested air-cooled condenser drops to up to 57% of the rated capacity between 2 cleanings at intervals of 5 months (beginning of April and end of August) due to fouling. This leads to a 5.6% reduction in waste incineration and 7.9% less electricity production in these 5 months. If, on the other hand, the LuKo is cleaned on demand, its output does not fall below 95%, which means that the slumps in production can be largely avoided.
Images and videos for application examples from the waste incineration plant sector in which the JetMaster combination system and the TubeMaster system were used.